High Voltage Counter Timer (HVCT) Model 7709
The IAP 7709 high voltage counter timer system is used to count Geiger-Muller detector output pulses. This system has a high voltage supply, which is used for Geiger-Muller detector bias.
Specification
System Menu
The HVCT 7709 has a 20 × 4 character LCD and displays the below information (for example):
- HV: 320V
- Set time: 123 Sec
- Real time: 123 Sec
- Count: 340000
Description
Set time: Display the time set by the user
Real time: Display the last time from the beginning of the counting
Counter: Display the count of the system
HV: Display the value of the detector voltage
Control inputs
- Keyboard: The keypad contains a set of keys for setting the counting time
- UP Key: time increases one time units with each time key press
- Down Key: time decrease one time units with each time key press
- Start: The start key is the press key that is installed on the front of the system. Pressing the start key, the system put in the count mode, and turn on the red LED in front of it. Pressing it again, it stops counting, turn the LED off and display counting at this moment. If pressed again, continues counting until the end of SET TIME.
- Reset: By pressing this key, the value of time and count is zero.
- HV: 10 turn potentiometer, adjustment in the range of 0-1000 V with an accuracy of ± 5 V
- Int/Ext: This key is the two positions that is installed behind the device. When this key is in the internal position, the output pulse from a Geiger-Muller is counted. If this key is placed in the external mode, the system counts the pulses applied to the Ext.Count input.
- Start: It is a BNC connector that is mounted behind the system for counting pulse with maximum + 6 V.
- Stop: The Ext.Stop is a BNC connector that is mounted behind the system for stopping counting pulse with maximum + 6 V.
- Input: G-M: A BNC connector on the front of the system for detector power
- Outputs
- Window: It is a BNC connector on the back of the system that its voltage is +3.3 V and + 0 V in active and inactive state, respectively.
- G-M Pulse: It is a BNC connector on the back of the system.
- HV: It is a BNC connector on the back of the system, the amount of adjustable voltage is accessible on this connector.
Installation Requirements
- Laboratory
- A table for placing device
- Bin power supply model 8000 or 8010
- BNC cable
- PMT device
- Detector
- Amplifier and preamplifier
- The equipped room with an air conditioning for constant temperature and humidity
- Power
- Oscilloscope
Long Term Warranty And After Sales Service
The warranty service includes the repair or service of the instrument and the free provision of services for replacing parts and repair wages for one year, but the warranty does not apply on the following cases:
- Transport damages, electrical fluctuations, fire or heat, contact or penetration of water and corrosive chemicals, intense dust, lightning, natural disasters.
- Instruments manipulated or repaired by persons other than the company’s representatives.
- Any kind of manipulation or damage on installed holograms on the instrument.
- Any displacement after installation without informing the company.
- The warranty does not cover consumables.
- After sales service is for 10 years with payment.